{"id":257764,"date":"2026-11-17T00:15:06","date_gmt":"2026-11-16T23:15:06","guid":{"rendered":"https:\/\/efecomunica.efe.com\/?p=257764"},"modified":"2026-11-17T13:40:43","modified_gmt":"2026-11-17T12:40:43","slug":"from-physics-to-factory-naeds-pv-1-delivers-the-tandem-era-at-96000-wph","status":"publish","type":"post","link":"https:\/\/efecomunica.efe.com\/en\/from-physics-to-factory-naeds-pv-1-delivers-the-tandem-era-at-96000-wph\/","title":{"rendered":"From Physics to Factory: NAED\u2019s PV-1 delivers the tandem era at 96,000 WPH"},"content":{"rendered":"<p>Statement issued by the company (Announcement)<\/p>\n<p>96,000 wafers an hour. Six lines. One tandem platform<\/p>\n<div>\n<p>Four years. Thousands of hours. Countless tests. And now, the moment the industry has been waiting for. NAED Energy Holding Inc. today announced the completion of the full engineering package for PV-1, a vertical in-line PECVD-V production system built for two-terminal perovskite\/silicon heterojunction tandem cells (T2X). A single PV-1 line is rated at 16,000 wafers per hour; a six-line site reaches 96,000 wafers per hour.<\/p>\n<p>The package runs from device physics through 14 complete machine build sets, utility hook-ups, a full bill of materials and large-format print sets, ready for scale. Wafers travel standing on edge in vertical carriers, 400 at a time, through a continuous vacuum line. Halfway through, the whole carrier is turned 180\u00b0 in vacuum so both faces are coated without a single wafer being touched. No hands, from beginning to end.<\/p>\n<h2>The Tandem Production Breakthrough Everyone Was Waiting For<\/h2>\n<p>Key figures:<\/p>\n<ul>\n<li><strong>16,000 wafers per hour <\/strong>per line; 96,000 wafers per hour for a six-line site<\/li>\n<li><strong>16,007 wph verified <\/strong>average across three certified 24-hour production runs, all within the TDS-001 gate<\/li>\n<li><strong>34.4 % <\/strong>modelled T2X cell efficiency; 7.48 W per half-cell at standard test conditions<\/li>\n<li><strong>788.1 MW DC per year <\/strong>per line and 4,728.5 MW (\u2248 4.7 GW) for six lines, on a production basis<\/li>\n<li><strong>Wet bench plus 13 PV-1 machines <\/strong>per line, from wet bench to rear print<\/li>\n<li><strong>All acceptance gates passed: <\/strong>24\/24 tool acceptance criteria, 12\/12 accelerated reliability sequences, 19\/19 calibrated instruments<\/li>\n<li><strong>709 part numbers <\/strong>in the complete bill of materials<\/li>\n<li><strong>Five US utility applications, <\/strong>patent pending<\/li>\n<\/ul>\n<h2>The Physics: Why Tandem<\/h2>\n<p>A single silicon junction loses most of the energy of blue and green photons as heat. T2X stacks a wide-bandgap perovskite top cell (about 1.7 eV) on a silicon heterojunction bottom cell (about 1.1 eV). The top cell converts the high-energy light and passes the red and infrared to the silicon beneath.<\/p>\n<p>In a two-terminal tandem the two subcells are connected in series: they share one current and their voltages add. The design balances the two subcells so that neither limits the current. At that balance point the modelled T2X half-cell delivers 7.48 W, a conversion efficiency of 34.4 % under standard test conditions (AM1.5G, 1,000 W\/m\u00b2, 25 \u00b0C).<\/p>\n<h2>The Finished T2X Cell<\/h2>\n<p>The finished T2X cell is a G12 half-cell, 210 \u00d7 105 mm, with 217.2 cm\u00b2 of active area. Each face carries 68 fine contact fingers at 3.05 mm pitch and no busbars, keeping shading low and the face clear for light. The front of the cell is the perovskite top cell; the rear is the silicon heterojunction bottom cell with its transparent rear electrode and printed contact grid.<\/p>\n<h2>The Line: From Wafer to Tandem-Ready Cell<\/h2>\n<p>PV-1 carries wafers standing on edge in vertical carriers, 400 at a time, through a continuous vacuum line. Halfway through, the whole carrier is lifted and turned 180\u00b0 in vacuum, so both faces are coated without a single wafer being touched (patent pending). The line runs through 14 stations:<\/p>\n<table>\n<tbody>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border: solid black 1pt;\"><strong>#<\/strong><\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-top: solid black 1pt; border-right: solid black 1pt; border-bottom: solid black 1pt;\"><strong>Station<\/strong><\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-top: solid black 1pt; border-right: solid black 1pt; border-bottom: solid black 1pt;\"><strong>Function<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\">1<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">Wet bench (Qyrion 1000)<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">Cleans and textures the silicon wafers<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\">2<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">V-Loader (VL-1)<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">Loads wafers edge-on into twin vertical carriers<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\">3<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">Load lock (LL)<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">Takes the carriers from atmosphere into vacuum<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\">4<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">Process module PM1<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">PECVD-V deposition, front face<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\">5<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">Transfer module TM1<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">Moves carriers between process modules under vacuum<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\">6<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">Process module PM2<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">PECVD-V deposition, front face<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\">7<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">Carrier rotation station (CRM-ST)<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">The 180\u00b0 whole-carrier turn, in vacuum<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\">8<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">Process module PM3<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">PECVD-V deposition, rear face<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\">9<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">Transfer module TM2<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">Vacuum transfer<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\">10<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">Process module PM4<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">PECVD-V deposition, rear face<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\">11<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">Unload lock (UL)<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">Returns the carriers to atmosphere<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\">12<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">Unloader (UN-1)<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">Transfers wafers to trays without contact<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\">13<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">In-line PVD (ITO-1)<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">Transparent conductive and interconnect layers<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\">14<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">Rear print and cure (RP-1)<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">Prints and cures the rear contact grid<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Ten doors per line isolate the vacuum stations: two atmospheric lock doors and eight slit valves, each interlocked so that a door opens only when both sides are matched.<\/p>\n<h2>The Engineering Record<\/h2>\n<p>Every machine on the line is engineered to build level, and the whole line is documented at print level on large-format 36 \u00d7 24 in sheets. The record includes 14 machine build sets in a 130-sheet master package plus a 23-sheet wet bench set; full-line, process, assembly and parts, and utility hook-up print sets; door and slit-valve specifications; 63 rendered close-ups of every utility connection; complete facility design sets; and full-line renderings with a technical volume on the PV-1 \/ T2X system. The eight large-format print sets alone run to 102 sheets.<\/p>\n<h2>The Complete Bill of Materials<\/h2>\n<p>The complete parts list holds 709 part numbers across the wet bench and the 13 PV-1 machines, numbered without gaps and totalled by formula.<\/p>\n<table>\n<tbody>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border: solid black 1pt;\"><strong>Total<\/strong><\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-top: solid black 1pt; border-right: solid black 1pt; border-bottom: solid black 1pt;\"><strong>Value<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\"><strong>Part numbers<\/strong><\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">709<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\"><strong>Hardware pieces per PV-1 line<\/strong><\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">2,807<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\"><strong>Hardware pieces, six lines<\/strong><\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">16,842<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\"><strong>Utility hook-up components per line<\/strong><\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">711<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\"><strong>Vacuum doors and slit valves, six lines<\/strong><\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">60<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Facility and Utilities<\/h2>\n<p>The PV-1 facility is designed in full, with every utility engineered and drawn from source to tool connection: power and controls, process cooling and ultrapure water with reclaim, bulk and specialty gases with monitored distribution, chemical supply and wastewater treatment, vacuum and point-of-use abatement, and process exhaust with gas detection.<\/p>\n<h2>Capacity and Verification<\/h2>\n<p>The capacity figures below are verified. Under NAED specification TDS-001, measured performance is published only after three consecutive 24-hour production runs under full automated load remain within \u00b13.0% of the 16,000 wph design takt, with zero catastrophic stops.<\/p>\n<p>The certified runs of 10\u201312 November 2026 produced 1,152,500 good wafers at an average of 16,007 wph (+0.04% versus design), with a run-to-run spread of 0.18%. All three runs passed the TDS-001 gate. Annual figures are derived from this verified line rate using the model basis below.<\/p>\n<table>\n<tbody>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border: solid black 1pt;\"><strong>Quantity<\/strong><\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-top: solid black 1pt; border-right: solid black 1pt; border-bottom: solid black 1pt;\"><strong>Per line<\/strong><\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-top: solid black 1pt; border-right: solid black 1pt; border-bottom: solid black 1pt;\"><strong>Six lines<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\"><strong>Rated throughput<\/strong><\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">16,000 wph<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">96,000 wph<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\"><strong>Good cells per year<\/strong><\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">119.14 million<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">714.8 million<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\"><strong>DC output per year, production basis<\/strong><\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">788.1 MW<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">4,728.5 MW<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\"><strong>DC output per year, at modelled T2X efficiency<\/strong><\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">890.1 MW<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">5,340.9 MW<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Model basis: 85.0% overall equipment effectiveness (yield included). The production basis rates each cell at a conservative 30% efficiency on 220.5 cm\u00b2 (6.6 W per cell). The second row applies the modelled 34.4% T2X efficiency on 217.2 cm\u00b2 (7.48 W per cell).<\/p>\n<h2>Testing and Qualification<\/h2>\n<p>Every PV-1 tool and the T2X cell have passed NAED\u2019s acceptance gates, with each result traced to a signed evidence record. Testing is carried out across eight dedicated laboratories totalling 1,420 m\u00b2.<\/p>\n<table>\n<tbody>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border: solid black 1pt;\"><strong>Gate<\/strong><\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-top: solid black 1pt; border-right: solid black 1pt; border-bottom: solid black 1pt;\"><strong>Standard<\/strong><\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-top: solid black 1pt; border-right: solid black 1pt; border-bottom: solid black 1pt;\"><strong>Result<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\"><strong>Production stability (TDS-001)<\/strong><\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">3 consecutive 24-hour runs within \u00b13.0% of design takt<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">3\/3 passed; 16,007 wph average, 0.18% spread<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\"><strong>Factory and site acceptance (FAT\/SAT)<\/strong><\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">24 vacuum, mechanical and process criteria<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">24\/24 passed<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\"><strong>Accelerated reliability, mini-modules<\/strong><\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">12 sequences to IEC 61215-2, IEC TS 62804 and ISOS protocols<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">12\/12 passed; 95.9\u201399.5% power retained (limit 95.0%)<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\"><strong>Instrument calibration<\/strong><\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">ISO\/IEC 17025 traceability to NIST and PTB<\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">19\/19 instruments in date, 0 overdue<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Acceptance highlights include a whole-chamber helium leak rate of 8.5 \u00d7 10\u207b\u00b9\u2070 mbar\u00b7L\/s against a 1 \u00d7 10\u207b\u2079 limit, a 41-second 180\u00b0 carrier turn inside a 57-second window, and a line index of 86.5 seconds against the 90-second design. In reliability testing, mini-modules retained 96.4% of their power after 1,000 hours of damp heat at 85 \u00b0C and 85% relative humidity, and 97.0% after 200 thermal cycles.<\/p>\n<h2>Intellectual Property<\/h2>\n<p>Five US utility applications cover the PV-1 line and the T2X cell, all assigned to NAED Energy Holding Inc. and patent pending.<\/p>\n<table>\n<tbody>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border: solid black 1pt;\"><strong>Application<\/strong><\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-top: solid black 1pt; border-right: solid black 1pt; border-bottom: solid black 1pt;\"><strong>Subject<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\"><strong>US 19\/853,551<\/strong><\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">Whole-carrier 180\u00b0 rotation module (CRM-ST)<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\"><strong>US 19\/853,651<\/strong><\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">PECVD \/ PVD shared-carrier system<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\"><strong>US 19\/866,828<\/strong><\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">T2X tandem cell<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\"><strong>US 19\/866,836<\/strong><\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">Carrier pin wafer-retention system<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt; border-left: solid black 1pt;\"><strong>US 19\/866,838<\/strong><\/td>\n<td style=\"vertical-align: top; text-align: left; padding-left: 10.0px; border-right: solid black 1pt; border-bottom: solid black 1pt;\">PV-1 principal production line<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>About NAED Energy Holding Inc.<\/h2>\n<p>NAED Energy Holding Inc. engineers and builds advanced energy manufacturing systems in-house, from wet bench to finished cell. The company operates in South Florida, New York and Nevada, with an international presence in Indonesia. Learn more at NAED.energy.<\/p>\n<p><strong>Forward-Looking Statements<\/strong><\/p>\n<p>This release contains forward-looking statements, including modelled cell efficiency, cell power and annual output derived from the verified line rate. Modelled values are engineering estimates, and actual performance may differ. NAED undertakes no obligation to update these statements except as required by law.<\/p>\n<pre><strong>Contacts<\/strong>\r\n<strong>Media: <\/strong>Malcom Longair, malcom.longair@naedcorp.com\r\n<strong>Technical: <\/strong>cto.fusion@naedcorp.com, (480) 475-6916, NAED.energy<\/pre>\n<p>Photos accompanying this announcement are available at<\/p>\n<p><a href=\"https:\/\/www.globenewswire.com\/Tracker?data=Yze4vFHTGOK2j2mytPooYMwukAYmsjmLnALYxitRfTOoPrnzTibs9nm65tMl7NUzWGnfr-gQQCVauAAicCZ1EV9LJkUgR32Fu_egMFBxwqv8HdxxUurPZDs76DQyuqx5oCRjdSvmZ0OqbIyEziVkKNjOjKonSlIRS1lI0nmIeaTw2KnpZOOkmeRhO0EmrUwdWkg3KkEMwVWE17BnkUAs2eksobjwB8JUtzJ1BP0_063LTl5XqJB7PP5Nq-9hTLvtrREk4SfN7Uai5wkrOXWoJA==\" target=\"_blank\" rel=\"noopener\">https:\/\/www.globenewswire.com\/NewsRoom\/AttachmentNg\/c294d22c-af62-4005-8e85-f7eba1ef1b7b<\/a><\/p>\n<p><a href=\"https:\/\/www.globenewswire.com\/Tracker?data=Yze4vFHTGOK2j2mytPooYMwukAYmsjmLnALYxitRfTOoPrnzTibs9nm65tMl7NUz_d11bIMuZhY8PWhGvpuraKlGc8XcaS6KlGiuWWOaGgFzz9agDHVUnHYhPSw80Ew7HzlkQ5jrw_NH8ATGllkeGbLUSkGaK3w3AdG9cAyQ0Joc4PKuQiuMS8ZjFJC8zQ1NaoPJQcb3OWUYcFl8QdAe_6H4ZVNJcFEKS3wosI8Fb2ode_de_m5DNGNJpBe0bv1ivEixcH6NYFdmE0slJbUswg==\" target=\"_blank\" rel=\"noopener\">https:\/\/www.globenewswire.com\/NewsRoom\/AttachmentNg\/886c4637-7595-4546-9af0-aa8e8b298f06<\/a><\/p>\n<p><a href=\"https:\/\/www.globenewswire.com\/Tracker?data=Yze4vFHTGOK2j2mytPooYMwukAYmsjmLnALYxitRfTOoPrnzTibs9nm65tMl7NUzJBxdJCU0m8HcGR8hinnTOj_sdBX0yHyvZDuIogpy55vHEVBVTc3itLXusKOFIIFMVRNd5HKFDWP3NiHdIzIdxNiDQuKVTNM_WAXd8eWn3X4D4xBkWkE1CKIohCD0tqwFZi5_u6-tL7FDaAurmh5mGf9Ydm8dtGxnb6xydV2mlhigGGCf-sUdRuDp5N1bRzhe_C9TShYjZq2YcJz7VmWg9g==\" target=\"_blank\" rel=\"noopener\">https:\/\/www.globenewswire.com\/NewsRoom\/AttachmentNg\/e24abc7c-a4fc-4508-8167-3a18168abc51<\/a><\/p>\n<p><em>AGENCIA EFE S.A.U.,S.M.E. shall not be liable for any information contained in this message and assumes no responsibility towards third parties in relation to its contents, being expressly exempt from any liability that the author may have in relation to the information in question. Agencia EFE reserves the right to distribute the press release on the news wire, or to publish it on EFE Comunica.<\/em><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Statement issued by the company (Announcement) 96,000 wafers an hour. Six lines. One tandem platform Four years. Thousands of hours. Countless tests. And now, the moment the industry has been [&hellip;]<\/p>\n","protected":false},"author":198164071,"featured_media":48434,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_wpcom_ai_launchpad_first_post":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[125518],"tags":[],"class_list":["post-257764","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-globenewswire-en"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>NAED\u2019s PV-1 delivers the tandem era at 96,000 WPH<\/title>\n<meta name=\"description\" content=\"NAED Energy Holding Inc. announces the completion of the full engineering package for PV-1, a vertical in-line PECVD-V production system.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/efecomunica.efe.com\/en\/from-physics-to-factory-naeds-pv-1-delivers-the-tandem-era-at-96000-wph\/\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"NAED\u2019s PV-1 delivers the tandem era at 96,000 WPH","description":"NAED Energy Holding Inc. announces the completion of the full engineering package for PV-1, a vertical in-line PECVD-V production system.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/efecomunica.efe.com\/en\/from-physics-to-factory-naeds-pv-1-delivers-the-tandem-era-at-96000-wph\/","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/efecomunica.efe.com\/en\/from-physics-to-factory-naeds-pv-1-delivers-the-tandem-era-at-96000-wph\/#article","isPartOf":{"@id":"https:\/\/efecomunica.efe.com\/en\/from-physics-to-factory-naeds-pv-1-delivers-the-tandem-era-at-96000-wph\/"},"author":{"name":"EFE","@id":"https:\/\/efecomunica.efe.com\/#\/schema\/person\/38c335f1ce4cd42430576ef5499343b8"},"headline":"From Physics to Factory: NAED\u2019s PV-1 delivers the tandem era at 96,000 WPH","datePublished":"2026-11-16T23:15:06+00:00","dateModified":"2026-11-17T12:40:43+00:00","mainEntityOfPage":{"@id":"https:\/\/efecomunica.efe.com\/en\/from-physics-to-factory-naeds-pv-1-delivers-the-tandem-era-at-96000-wph\/"},"wordCount":1397,"publisher":{"@id":"https:\/\/efecomunica.efe.com\/#organization"},"image":{"@id":"https:\/\/efecomunica.efe.com\/en\/from-physics-to-factory-naeds-pv-1-delivers-the-tandem-era-at-96000-wph\/#primaryimage"},"thumbnailUrl":"https:\/\/efecomunica.efe.com\/wp-content\/uploads\/2022\/10\/Notified-GlobeNewswire-Color-Large-1.jpg","articleSection":["Globenewswire"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/efecomunica.efe.com\/en\/from-physics-to-factory-naeds-pv-1-delivers-the-tandem-era-at-96000-wph\/","url":"https:\/\/efecomunica.efe.com\/en\/from-physics-to-factory-naeds-pv-1-delivers-the-tandem-era-at-96000-wph\/","name":"NAED\u2019s PV-1 delivers the tandem era at 96,000 WPH","isPartOf":{"@id":"https:\/\/efecomunica.efe.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/efecomunica.efe.com\/en\/from-physics-to-factory-naeds-pv-1-delivers-the-tandem-era-at-96000-wph\/#primaryimage"},"image":{"@id":"https:\/\/efecomunica.efe.com\/en\/from-physics-to-factory-naeds-pv-1-delivers-the-tandem-era-at-96000-wph\/#primaryimage"},"thumbnailUrl":"https:\/\/efecomunica.efe.com\/wp-content\/uploads\/2022\/10\/Notified-GlobeNewswire-Color-Large-1.jpg","datePublished":"2026-11-16T23:15:06+00:00","dateModified":"2026-11-17T12:40:43+00:00","description":"NAED Energy Holding Inc. announces the completion of the full engineering package for PV-1, a vertical in-line PECVD-V production system.","breadcrumb":{"@id":"https:\/\/efecomunica.efe.com\/en\/from-physics-to-factory-naeds-pv-1-delivers-the-tandem-era-at-96000-wph\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/efecomunica.efe.com\/en\/from-physics-to-factory-naeds-pv-1-delivers-the-tandem-era-at-96000-wph\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/efecomunica.efe.com\/en\/from-physics-to-factory-naeds-pv-1-delivers-the-tandem-era-at-96000-wph\/#primaryimage","url":"https:\/\/efecomunica.efe.com\/wp-content\/uploads\/2022\/10\/Notified-GlobeNewswire-Color-Large-1.jpg","contentUrl":"https:\/\/efecomunica.efe.com\/wp-content\/uploads\/2022\/10\/Notified-GlobeNewswire-Color-Large-1.jpg","width":1200,"height":650,"caption":"Tealium"},{"@type":"BreadcrumbList","@id":"https:\/\/efecomunica.efe.com\/en\/from-physics-to-factory-naeds-pv-1-delivers-the-tandem-era-at-96000-wph\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/efecomunica.efe.com\/"},{"@type":"ListItem","position":2,"name":"From Physics to Factory: NAED\u2019s PV-1 delivers the tandem era at 96,000 WPH"}]},{"@type":"WebSite","@id":"https:\/\/efecomunica.efe.com\/#website","url":"https:\/\/efecomunica.efe.com\/","name":"EFE Comunica","description":"Contenidos para empresas","publisher":{"@id":"https:\/\/efecomunica.efe.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/efecomunica.efe.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/efecomunica.efe.com\/#organization","name":"EFE Comunica","url":"https:\/\/efecomunica.efe.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/efecomunica.efe.com\/#\/schema\/logo\/image\/","url":"https:\/\/efecomunica.efe.com\/wp-content\/uploads\/2020\/12\/Logo-EFE-Comunica_png.png","contentUrl":"https:\/\/efecomunica.efe.com\/wp-content\/uploads\/2020\/12\/Logo-EFE-Comunica_png.png","width":1080,"height":486,"caption":"EFE Comunica"},"image":{"@id":"https:\/\/efecomunica.efe.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/EFEComunicaAgenciaEFE","https:\/\/x.com\/EFEcomunica","https:\/\/www.linkedin.com\/showcase\/efecomunica"]},{"@type":"Person","@id":"https:\/\/efecomunica.efe.com\/#\/schema\/person\/38c335f1ce4cd42430576ef5499343b8","name":"EFE","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/e5fcf26bedbd04dc20896c519164a13fe69c6913f5830d7db51543fa04eb30b4?s=96&d=identicon&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/e5fcf26bedbd04dc20896c519164a13fe69c6913f5830d7db51543fa04eb30b4?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/e5fcf26bedbd04dc20896c519164a13fe69c6913f5830d7db51543fa04eb30b4?s=96&d=identicon&r=g","caption":"EFE"},"sameAs":["http:\/\/efe.com"],"url":"https:\/\/efecomunica.efe.com\/en\/author\/efedesarrollo\/"}]}},"jetpack_likes_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/pcEg1r-153u","jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/efecomunica.efe.com\/wp-content\/uploads\/2022\/10\/Notified-GlobeNewswire-Color-Large-1.jpg","_links":{"self":[{"href":"https:\/\/efecomunica.efe.com\/en\/wp-json\/wp\/v2\/posts\/257764","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/efecomunica.efe.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/efecomunica.efe.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/efecomunica.efe.com\/en\/wp-json\/wp\/v2\/users\/198164071"}],"replies":[{"embeddable":true,"href":"https:\/\/efecomunica.efe.com\/en\/wp-json\/wp\/v2\/comments?post=257764"}],"version-history":[{"count":3,"href":"https:\/\/efecomunica.efe.com\/en\/wp-json\/wp\/v2\/posts\/257764\/revisions"}],"predecessor-version":[{"id":257917,"href":"https:\/\/efecomunica.efe.com\/en\/wp-json\/wp\/v2\/posts\/257764\/revisions\/257917"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/efecomunica.efe.com\/en\/wp-json\/wp\/v2\/media\/48434"}],"wp:attachment":[{"href":"https:\/\/efecomunica.efe.com\/en\/wp-json\/wp\/v2\/media?parent=257764"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/efecomunica.efe.com\/en\/wp-json\/wp\/v2\/categories?post=257764"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/efecomunica.efe.com\/en\/wp-json\/wp\/v2\/tags?post=257764"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}